📞 +86 158 8822 9669

0.75kV Outdoor Epoxy Current Transformer —
LV Metering CT, 5A to 1000A

Drop-in replacement for GE JAK-0C and Alta COM-6. Amorphous alloy core, anti-UV epoxy body, sealed secondary junction box — built for long-term outdoor metering on LV distribution systems.

Max system voltage 0.75 kV
Primary 5 – 1000 A
Secondary 1A / 5A
ANSI 0.15 · IEC 0.15S
UTCT 0.75kV outdoor epoxy resin current transformer
UTCT · outdoor epoxy resin insulated current transformer
✓ Factory-direct from Wenzhou, China
✓ Routine test report with every unit
✓ Quotation within 24 hours
✓ Small trial orders accepted

Where the UTCT is used in the Philippines

Low-voltage (0.75kV) outdoor CTs are the standard way to meter LV feeders, service entrances and sub-distribution circuits where the current is too high for a direct-connected meter.

kWh

CT-operated kWh metering

Feeds 1A / 5A inputs of CT-operated energy meters on LV feeders, service drops and tenant sub-metering.

PNL

Panel builders & meter centers

Round-window, cable-through design fits standard LV metering pans and metering cubicles without re-machining.

EC

Cooperatives & distribution utilities

Revenue metering where ANSI C57.13 accuracy class 0.15 is specified for billing.

RPL

Retrofit & replacement

Same ratings and footprint as GE JAK-0C / Alta COM-6 — swap the unit, keep the mounting and the cable entry.

Direct replacement for GE JAK-0C & Alta Series COM-6

If you are still running GE JAK-0C or Alta COM-6 units, the UTCT is a drop-in substitute — same ratings, same accuracy class, same installation footprint.

ParameterGE JAK-0CAlta Series COM-6UNISUN UTCT
Max system voltage0.75 kV0.75 kV0.75 kV (750 V)
Rated primary current5 – 1000 A5 – 1000 A5 – 1000 A
Secondary current5 A (1 A on request)5 A (1 A on request)1 A or 5 A, customized
Accuracy classANSI 0.15ANSI 0.15ANSI 0.15 / IEC 0.15S
Installation footprintOriginal mountingOriginal mountingSame — no re-design needed
WindowRound window, cable throughRound window, cable throughRound window, cable through
Secondary boxJunction boxJunction boxSealed, stainless steel lead-seal screws
StandardANSI C57.13ANSI C57.13ANSI C57.13 / IEC 61869

Model cross-reference: GE JAK-0C, JAK 0C and Alta COM-6

If you are searching for a GE current transformer replacement, the UNISUN UTCT covers every ratio GE listed for the JAK-0C range, 100:5 through 1000:5, with the same 0.75 kV maximum system voltage, the same ANSI 0.15 / IEC 0.15S accuracy class and the same Ø80 mm window. Below is the model-to-model cross reference we use when a customer sends a nameplate photo.

Model you have nowRatios we supplyOrder as
GE JAK-0C current transformer (also written GE JAK 0C, JAK-0C, JAK-0C CT)100:5 · 200:5 · 300:5 · 400:5 · 500:5 · 600:5 · 800:5 · 1000:5, single or dual ratioUTCT 400:5 (state ratio)
Alta COM-6 current transformer (also written COM-6, COM 6, Alta COM-6 CT)100:5 – 600:5, 1 A or 5 A secondaryUTCT 400:5 (state ratio)
GE JAK-0C wound-primary, 1 A secondaryAny ratio in the table above with 1 A secondaryUTCT 400:1

How to confirm: send the nameplate photo or the JAK-0C catalog number and we reply in writing with the equivalent GE JAK-0C replacement model, the drawing and the price. Nothing on the mounting or the cable entry has to change — the COM-6 and JAK 0C footprints are matched.

UNISUN ELECTRIC is a current transformer manufacturer in the Philippines market supply chain — we ship direct from our factory to Manila, Cebu, Davao and Subic, and we also act as an instrument transformer supplier Philippines buyers use for CT/PT packages: current transformers, voltage transformers, combined metering units, 11 kV and 33 kV outdoor epoxy CTs. Every unit ships with a routine test report.

Ratings shown for the original models are those published for the types this product replaces. Send us your nameplate photo or the original datasheet and we confirm the equivalent UTCT model in writing.

Technical data

Standard range below — ratios, burden and accuracy class can be built to your project specification.

ItemValue
TypeUTCT (standard)  ·  ERCT (extended range) — see note below
Accuracy rangeUTCT: from 10% of rated current to rating factor  ·  ERCT: from 1% of rated current to rating factor
ConstructionOutdoor, epoxy resin cast, dry type
Max. system voltage0.75 kV (750 V)
Rated frequency50 / 60 Hz
Rated primary current5 / 10 / 15 / 20 / 25 / 30 / 40 / 50 / 75 / 100 / 150 / 200 / 300 / 400 / 500 / 600 / 800 / 1000 A
Secondary current1 A or 5 A (customized)
Accuracy classIEC: 0.15S / 0.15 / 0.3 / 0.6  ·  ANSI: 0.15
Rated output (burden)Up to 20 VA
CoreAmorphous alloy (metering) · CRGO (protection)
WindingHigh-purity enameled copper wire, electrolytic copper primary
Insulation / housingAnti-UV outdoor epoxy resin, 10-year outdoor service life
Secondary boxSealed design, waterproof, stainless steel lead-seal screws, cable exit from top
StandardsANSI C57.13 · IEC 61869
Ambient temperature−20 °C to +70 °C
HumidityMonthly average 95 %, daily average 90 %
Installation altitude≤ 1000 m

ERCT — extended range version for low load-factor meters

Same outdoor epoxy body, same footprint, same ratio — but the 0.15 class is held from 1% of rated current up to the rating factor, not only from 10%. That is what Philippine tenant metering, sub-metering and EV-charging circuits need when the load sits far below the CT rating most of the day.

1%

Billing accuracy at light load

A standard CT is specified from 10% of rated current. ERCT keeps 0.15 class down to 1% — so a 400:5 CT still meters correctly when the load drops to a few amps at night.

RF

Holds up to the rating factor

Accuracy is guaranteed across the whole range, from 1% of rated current up to the rating factor — no accuracy gap between light load and overload.

=

Drop-in, same drawing

Identical body, mounting and secondary box as the UTCT. Only the model code changes: ERCT 400:5 instead of UTCT 400:5.

ItemUTCT (standard)ERCT (extended range)
Accuracy class0.15S (IEC) / 0.15 (ANSI)0.15 class from 1% of rated current to RF
Class guaranteed from10% of rated current1% of rated current
Ratios / secondary5:5 – 1,000:5 · 1 A or 5 ASame · single or dual ratio
Body0.75 kV outdoor epoxy, sealed boxIdentical body and footprint
Typical useSteady loads near rated currentTenant metering, sub-metering, EV charging, seasonal / night-heavy load
Order codeUTCT 400:5ERCT 400:5

Why buyers in the Philippines choose UNISUN

We manufacture instrument transformers in our own factory in Wenzhou, China — you buy direct, with the drawings and test documents you need for approval.

0.15S
Accuracy up to IEC 0.15S / ANSI 0.15 for revenue metering
10 yr
Anti-UV epoxy rated for long-term outdoor installation
24 h
Technical confirmation and quotation reply time
1 pc
Trial order accepted before volume purchase

✅ Factory-direct price

No trading company in between — a direct manufacturer quotation for your quantity and port.

✅ Documents for approval

Outline drawing, routine test report with every unit, type test reports on request.

✅ Built to your spec

Ratio, secondary current, burden, accuracy class, lead length and terminal arrangement to your requirement.

How to order — what we need to quote

Send these six items (or just a photo of the old nameplate) and you get a confirmed model and price within 24 hours.

1

Ratio

e.g. 200/5 A, 400/5 A, 600/5 A — or the load current so we can size it.

2

Secondary

1 A or 5 A, and the burden in VA (max 20 VA).

3

Accuracy class

0.15S / 0.3 for billing metering, 0.6 for indication.

4

Quantity & port

Pieces per ratio and destination port (Manila / Cebu / Davao).

Frequently asked questions

Questions we get from panel builders, electrical contractors and metering projects in the Philippines.

What is the UTCT used for?
UTCT is a low-voltage (0.75kV) outdoor epoxy resin current transformer used for metering on LV distribution feeders and service cables — typically feeding kWh / energy meters, panel meters and revenue metering units where the load current is too high to pass directly through the meter.
Is it really a drop-in replacement for GE JAK-0C and Alta COM-6?
Yes. UTCT matches the same rated current range (5–1000 A), the same max system voltage 0.75 kV, the same accuracy class (ANSI 0.15 / IEC 0.15S) and the same installation footprint, so the existing mounting and cable entry can be reused. Send a nameplate photo and we confirm the equivalent model in writing before you order.
Which accuracy class do I need for billing metering?
For revenue / billing metering, specify ANSI 0.15 (or IEC 0.15S). For indication or sub-metering, 0.3 or 0.6 is normally sufficient. Tell us the meter type and the utility requirement, and we recommend the class.
Can you supply 1A secondary instead of 5A?
Yes — secondary can be 1 A or 5 A, and rated output can be designed up to 20 VA. Long cable runs between CT and meter usually favour 1 A secondary; tell us the distance and we advise.
What is the ERCT extended range version?
ERCT is the same transformer built as an extended-range CT: the 0.15 accuracy class is held from 1% of rated current up to the rating factor, instead of only from 10%. Use it where the load runs far below the CT rating most of the time — tenant and sub-metering, seasonal or night-heavy demand, EV charging — so billing stays accurate at light load. Body, footprint and ratios are identical to the UTCT; only the model code changes (e.g. ERCT 400:5).
Do you provide test reports and drawings?
Every unit ships with a routine test report. Outline dimension drawings are supplied with the quotation, and type test reports are available on request for utility approval.
What is the MOQ, lead time and payment term?
Small trial orders are accepted. Typical production lead time is 25–35 days after drawing confirmation, plus sea freight to Manila, Cebu or Davao. Standard payment term is TT 30 % deposit / 70 % before shipment after factory acceptance test.

Request price & datasheet

Fill in the ratio and quantity — we reply within 24 hours with the confirmed model, unit price and delivery time to your port.

Prefer chat? WhatsApp +86 158 8822 9669 · Email nico@unisun-electric.com

Need the equivalent of your old GE JAK-0C today?

Send a photo of the nameplate on WhatsApp — we reply with the matching UTCT model and price.

Chat on WhatsApp

Other instrument transformers we manufacture

Same factory, same testing — CT and PT for indoor and outdoor, epoxy cast and oil immersed, from 0.66kV up to 36kV. Every unit ships with a routine test report.

💬 WhatsApp Us for Price